234. During the sinking of a shaft, the automatic overspeed protective device of an electrical hoist shall be adjusted so that the speed of the hoist is reduced to less than 30% of the normal operating speed when the bucket is at the lower chair level and less than 3 m (9.8 ft) per second between the lower chair and the bottom of the shaft.